Canadian Vaccine Storage Guidelines 2026: November SOP Update Checklist
On November 16, 2026, the Public Health Agency of Canada updated the Canadian Immunization Guide’s storage and handling chapter. The previous chapter content was removed and replaced with a direction to use PHAC’s National Vaccine Storage and Handling Guidelines for Immunization Providers, 2026.
For pharmacies and clinics, this is a useful trigger to update references, training material and emergency procedures. It is not a product recall, and it does not mean every existing refrigerator suddenly became unsuitable. The practical task is to confirm that local procedures now point to the current national framework while continuing to follow provincial, territorial and local immunization requirements.
What changed in November 2026?
The Canadian Immunization Guide table of updates records the November change. Rather than maintaining a separate storage chapter, the Guide now sends providers to the more comprehensive 2026 national document, which covers personnel, equipment, monitoring, incident management, distribution and disposal.
The 2026 guidelines were published in September and replace the 2015 national guidelines and the 2021 interim COVID-19 vaccine storage guidance. PHAC also states that the national document supplements—not replaces—jurisdictional policies. A clinic should therefore update its source list without deleting applicable provincial or local instructions.
A seven-point SOP update checklist
1. Replace obsolete references
Search routine storage, receiving, monitoring, transport, outage and cold-chain-break procedures for links or citations to the former Canadian Immunization Guide chapter, the 2015 national guideline or interim COVID-19 storage guidance. Replace those references with the 2026 national guideline and record the revision date in the document-control history.
2. Name a primary coordinator and a trained delegate
PHAC recommends a designated vaccine coordinator and a backup or delegate. The SOP should identify both roles, their after-hours contact path and who has authority to respond to an alarm, arrange alternate storage and contact the jurisdictional immunization program.
3. Keep three procedures distinct
A useful manual separates:
- routine storage and handling;
- urgent procedures for equipment failure, power loss or other emergencies; and
- cold-chain-break assessment, documentation and escalation.
This prevents a door-open alarm, a prolonged outage and a confirmed temperature excursion from being handled as though they were the same event.
4. Reconcile continuous monitoring with daily checks
The 2026 guideline calls for equipment operation to be monitored twice daily and says automated logging does not eliminate real-time checks. Document who reviews temperatures at the start and end of the workday, how weekends and closures are handled, how data are retained, and who reviews missed readings or alarm events.
5. Review the refrigerator record—not just the setpoint
PHAC identifies purpose-built vaccine refrigerators as the preferred type for vaccine inventories and emphasizes appropriate monitoring, placement and maintenance. Keep a unit-specific record that includes the model, serial number, required range, installation location, alarm settings, monitoring-device details, calibration records, maintenance history and emergency-power status.
Rated cabinet volume is not the same as usable vaccine capacity. Baskets, required spacing, airflow and the clinic’s qualified loading pattern determine how much inventory can be stored appropriately.
6. Define what every backup system actually powers
A power-failure alarm, low-battery alarm or controller battery does not establish that the compressor continues to run. Your SOP should state separately:
- monitoring continuity: whether temperature data continue to be recorded;
- alarm continuity: whether local or remote notifications continue;
- cooling continuity: what actually supplies the refrigeration system.
If a UPS is used, PHAC says it should detect power loss automatically and support the attached cold-chain equipment for the expected outage duration. The electrical design must account for the refrigerator’s actual voltage, running load, compressor start-up demand and required runtime. A building generator similarly needs documented capacity, automatic-transfer behaviour, fuel and testing procedures.
7. Record the review and train affected staff
PHAC recommends annual protocol review and training for staff who handle vaccines or interact with storage areas. Record the revision, affected procedures, staff training date and any corrective actions. Include receiving, maintenance, janitorial, security and facilities personnel where their work could affect storage equipment or power.
A current equipment example: Haier HYC-118
As of November 17, 2026, the Haier HYC-118 solid-door undercounter medical refrigerator is active and available for online purchase from 360 Medical. Its current manufacturer documentation lists the following features:
| Verified item | Published specification | Practical implication |
|---|---|---|
| Temperature range | 2°C to 8°C | Matches the common refrigerated-vaccine range, subject to each product monograph and local program requirements. |
| Cabinet capacity | 118 L / 4.2 cu. ft. | Useful for comparing cabinet size, but not a promise of usable or qualified vaccine capacity. |
| Exterior dimensions | 23.5 × 25.0 × 31.9 in. | Supports undercounter site planning; required clearances and delivery access still need confirmation. |
| Cooling and door | Forced-air cooling; solid door | The solid door can help limit light exposure, while shelving and baskets must still preserve airflow. |
| Electrical | 115 V / 60 Hz, 1.4 A | Facilities staff can use these values when confirming the receptacle, circuit and any engineered backup-power system. |
| Alarms | High/low temperature, power failure, sensor error, low battery and door ajar | Supports local event detection; the alarm list does not mean the refrigerator keeps cooling during an outage. |
| Remote connection | Remote alarm interface | Can support an external notification workflow when connected and tested. It is not documented as a cloud service or USB data-export system. |
| Published energy figure | 0.42 kWh per 24 hours | Useful for facility planning under the manufacturer’s test basis; actual consumption depends on site and use. |
These values were checked against the current 360 Medical listing and Haier Biomedical’s manufacturer specification sheet. Equipment features can support an SOP, but they do not by themselves establish regulatory compliance or vaccine suitability.
Backup power versus an ice-lined refrigerator
The 2026 guideline discusses generators and UPS systems as contingency options. These systems can maintain refrigeration only when they are correctly sized, installed and maintained for the actual equipment load.
An ice-lined refrigerator uses stored thermal mass to slow temperature rise during a power interruption. That is different from powering the compressor. A stated holdover period applies only under the manufacturer’s documented test conditions, which may depend on ambient temperature, loading, door openings and initial stabilization. Before selecting an ice-lined unit, obtain the exact model’s current holdover conditions, availability, monitoring features and electrical requirements.
Neither approach removes the need for monitoring, named responders, alternate storage and a transfer plan. For a practical exercise, use our vaccine refrigerator power-outage tabletop drill.
What should clinics do now?
- Update the source list in every vaccine-storage SOP.
- Compare procedures against the 2026 national guideline and current jurisdictional requirements.
- Confirm coordinator, delegate and after-hours access information.
- Test temperature review, alarm notification and emergency-contact workflows.
- Document what remains powered during an outage—and for how long.
- Verify alternate storage capacity before it is needed.
- Record the review and train affected staff.
Facilities replacing or adding equipment can compare current medical and vaccine refrigerators by required temperature range, cabinet format, alarms, monitoring connections, dimensions and electrical needs. Confirm availability and the latest model documentation before ordering.
Primary sources
- Public Health Agency of Canada: Storage and handling of immunizing agents, revised November 2026
- Canadian Immunization Guide: Table of updates
- PHAC: National Vaccine Storage and Handling Guidelines for Immunization Providers, 2026
- Haier Biomedical: HYC-118 manufacturer specification sheet
This article provides general operational guidance. Follow the vaccine product monograph, current provincial or territorial requirements, local public health instructions, equipment documentation and your organization’s approved procedures.