Checklist for Daily Winter Checks on Laboratory Refrigerators

Canadian winters act as a severe stress test for laboratory equipment. Aggressive building heating, low humidity, and fluctuating temperatures create a hostile environment. As HVAC systems combat sub-zero conditions, your ultra low freezer and pharmaceutical refrigerators must work harder to maintain stability. Neglecting these seasonal demands risks compressor burnout and sample degradation, making a specialized daily routine essential for data survival.
How does winter impact your ultra low freezer and fridge performance?
Dryness and volatility are the primary winter threats, often pushing equipment to its operational limits. Humidity drops below 20% compromise gaskets and create static hazards for control boards, while building temperature setbacks stress cooling systems with rapid ambient fluctuations.
Consistency is important. According to a study, effective strategies, such as web-based programs, are needed to improve vaccine storage conditions in general practices (Thielmann et al., 2019). This logic applies universally; a specific winter strategy is essential to maintain sample integrity.
Here is your daily checklist to secure your cold storage during the heating season.
1. Is the ambient room temperature staying within range?

It seems counterintuitive, but your lab might be getting too hot or too cold for your equipment. In winter, many buildings rely on perimeter heating; radiators or baseboard heaters running along exterior walls. If your refrigerators are pushed against these walls, they might be inhaling hot air directly from a heater.
Conversely, if your lab lowers the heat to 15°C (59°F) over the weekend to save energy, the oil in your refrigerator’s compressor can become viscous, making it difficult for the unit to start.
-
The Check: Verify that no portable heaters are pointed at the unit and that perimeter heating is not cooking the back of the fridge.
-
The Action: Ensure the ambient temperature remains between 18°C and 25°C. If the lab feels chilly on Monday morning, check the unit's temperature log immediately to see if it struggled to cycle overnight.
2. Do the door gaskets pass the "Tactile Test"?
Low humidity is a gasket killer. In winter, indoor relative humidity can plummet. This dry air leeches moisture from the rubber or silicone seals of your unit, causing them to shrink, harden, and crack. A brittle gasket cannot form a hermetic seal.
Once the seal is compromised, warm lab air leaks into the cabinet constantly. This forces the compressor to run without pause, leading to overheating and failure.
-
The Check: Run your fingers along the gasket. It should feel supple and provide a slight resistance. If it feels hard, plastic-like, or if you see visible cracks, it is failing.
-
The Action: Perform the "paper test." Close the door on a piece of paper. If you can pull it out without resistance, the magnet and the rubber are not sealing. This requires immediate replacement.
3. Is the condenser filter choked with "Winter Dust"?
Dust character changes in the winter. It becomes finer, drier, and more statically charged. This allows it to cling aggressively to the intake vents and condenser coils of your laboratory refrigerator. A clogged filter chokes the airflow, preventing the unit from expelling heat.
-
The Check: Inspect the front grille or the rear condenser area. Look for a grey, fuzzy mat of lint and dust.
-
The Action: Because winter dust is lighter, it accumulates faster. Check this weekly rather than monthly during the heating season. Use a vacuum to clear the airflow path immediately if any buildup is visible.
4. Are you monitoring for static discharge risks?
Static electricity is a silent destroyer of digital electronics. In a dry winter lab, walking across the floor can generate a charge of 20,000 volts or more. When you touch the digital control panel of your ultra low freezer, that spark can fry the microprocessor or corrupt the temperature settings.
-
The Check: Note if you feel shocks when touching metal surfaces in the lab.
-
The Action: Install a grounding mat in front of the unit or touch a neutral metal surface (like a table leg) before touching the refrigerator's control panel. This simple habit protects the brain of your machine.
5. Is there unexplained ice buildup?
In a dry environment, any moisture inside the unit (from samples or open containers) will try to migrate to the coldest surface; the evaporator coils. While some frost is normal in manual-defrost units, rapid ice formation in winter often points to a specific failure: a leak.
Since the air outside the unit is dry, you might not see external condensation. Instead, the moisture transfer happens internally.
-
The Check: Look for "snow" or heavy frost near the door hinge or on the ceiling of the unit.
-
The Action: If you see localized frost, it confirms a gasket leak (warm air entering). If the ice is uniform, check your defrost settings. Remove ice immediately, as it acts as an insulator and reduces cooling efficiency.
6. Have you reviewed the 24-hour data log?

Spot-checking the temperature at 9:00 AM and 5:00 PM is not enough, especially given the building heating cycles mentioned earlier. You need to know what the unit is doing at 3:00 AM when the building is darkest and coldest.
-
The Check: Download or view the temperature graph for the last 24 hours.
-
The Action: Look for a "sawtooth" pattern (rapid up and down cycling). This often indicates the compressor is short-cycling. Also, look for slow drifts in temperature that correlate with building heating schedules.
Don't Let the Freeze Burn Your Budget
Winter demands vigilance as dry air and heating fluctuations infiltrate the lab. Protecting samples requires proactive equipment management. If you detect brittle gaskets or erratic temperatures, do not wait for spring to act.
360 Degree Medical is your premier partner for Canadian cold storage solutions. Whether you need a robust new laboratory refrigerator or expert advice, we are here to help.
Call us today at 1-800-209-2082. Keep your standards high and your temperatures low.
Leave a comment