| Temperature Range | 2°C to 8°C |
| Default Set Point | 5°C |
| Cabinet Class | Counter Top |
| Door | Glass |
| Capacity (Cu.Ft/Liters) | 2.4 / 68 |
| Exterior Dimensions WxDxH (inch) | 19.5 x 22.8 x 26.0 |
| Exterior Dimensions WxDxH (cm) | 49.5 x 58.0 x 66.0 |
| Interior Dimensions WxDxH (inch) | 16.3 x 15.2 x 19.9 |
| Interior Dimensions WxDxH (cm) | 41.5 x 38.5 x 50.5 |
| Weight (lb) | 83.8 |
| Operating Noise (dB(A)) | 41 |
| Power Supply (V) | 115 |
| Frequency (Hz) | 60 |
| AMP (A) | 1.7 |
| Power (Watt) | 150 |
| Plug Type | Nema 5-15p |
| Cooling Technology | Forced Air Cooling |
| Certification | cUL |
| Display Screen | Digital LED |
| Settings Security | Protected |
| Visual / Audible Alarm | Yes / Yes |
| Power Failure Alarm | Yes |
| Adjustable High/Low Temperature Alarm | Yes |
| Door Ajar Alarm | Yes |
| Sensor Failure | Yes |
| Low Battery Alarm | Yes |
| Remote Contacts | Yes |
| USB Data Logger | No |
| Battery Back-up (Controller / USB Data Logger if applicable) | Yes |
| Probe Hole | Yes |
| Automatic Defrost | Yes |
| Light | Yes |
| Door Lock with Key | Yes |
| Castors | No |
| Feet | Yes - 4 |
| Standard Hinge Side | Right |
| Door Swing | Right |
| Reversible Door | No |
| Self Closing Door | No |
| Adjustable Shelves | 2 Shelves/ 1 Basket |
| Refrigerant | HC |
| Shelves Material | Steel wire, Coated with plastic |
Units Purchased on or after January 1, 2024
2-Year Parts Coverage
1-Year Labour Coverage
5-Year Compressor Warranty
1-Year Full Unit Replacement Assurance*
* If a verified refrigerant leak or compressor failure occurs within the first year of ownership, the unit will be replaced in full at no cost to the customer.
Units Purchased before January 1, 2024
1-Year Parts Coverage
1-Year Labour Coverage
5-Year Compressor Warranty
*Conditions apply.
All warranties become effective on the date the unit is received.
| Spec Sheet | Download Spec Sheet |
| User Manual | Download User Manual |
We receive this question on a regular basis here at 360 Medical and hope this information will help medical personnel understand why storing temperature sensitive vaccines, medications, products or samples is not ideal in a standard domestic refrigerator.
Having the proper refrigeration equipment is the first important step to ensuring product safety and efficiency at your facility. You also need to have appropriate vaccine storage and handling practices and procedures in place. By doing so you can maintain vaccine quality and potency and also minimize waste.